Precision Electrical
Testing Instruments

Guangdong ETCR Electronic Technology Co., Ltd. delivers high-accuracy Earth Resistance Testers, Insulation Resistance Testers, Clamp Meters, Power Quality Analyzers, and advanced monitoring systems for industrial, power grid, and telecom applications.

ETCR Instruments Testing Equipment

About ETCR

Guangdong ETCR Electronic Technology Co., Ltd. is a professional manufacturer specializing in the research, development, and production of high-precision electrical testing instruments. With years of technical expertise, ETCR has become a trusted name in the global market for reliable, innovative, and safe electrical measurement solutions.

Our product line spans Earth Resistance Testers, Insulation Resistance Testers, Clamp Meters, Power Quality Analyzers, Battery Testers, Thermal Imagers, and specialized monitoring systems. Designed for durability and accuracy, ETCR instruments meet international safety standards and are widely used in power utilities, industrial plants, telecommunications, and infrastructure projects.

100+
Products
50+
Countries
15+
Years Experience
ETCR EM6670D Clamp Meter

Our Products

High-precision instruments for every electrical testing need

EM3040A Ground Resistance Tester

EM3040A Ground Resistance Tester

With auxiliary ground stake alert function for enhanced safety and accuracy in grounding system evaluation.

  • • 4-Pole & 3-Pole Testing
  • • Stake Alert System
  • • 0.01Ω ~ 20kΩ Range
  • • Data Hold & Auto Power Off
Clamp Ground Resistance Tester

Clamp Earth Resistance Tester

Non-invasive measurement for grounding systems without disconnection. Ideal for live systems.

  • • Clamp-on Technology
  • • 0.1Ω ~ 1200Ω Range
  • • No Auxiliary Electrodes
  • • High Noise Immunity
High Voltage Insulation Resistance Tester

High Voltage Insulation Resistance Tester

Test insulation integrity with selectable test voltages up to 10kV.

  • • 500V ~ 10kV Output
  • • PI, DAR, DD Functions
  • • Large Memory Storage
  • • Safety Discharge
EM6530 Clamp Meter

EM6530 Clamp Multimeter

High-accuracy AC/DC clamp meter with multimeter functions for comprehensive diagnostics.

  • • AC/DC Current & Voltage
  • • Resistance, Capacitance
  • • Frequency & Duty Cycle
  • • True RMS Measurement
EM6670D Clamp Meter

EM6670D Clamp Meter

Advanced clamp meter with data logging, Bluetooth, and power quality analysis.

  • • 0.1mA ~ 2000A Range
  • • Bluetooth Data Transfer
  • • Harmonic Analysis
  • • Touchscreen Interface
Digital Earth Resistance Tester

Digital Earth Resistance Tester

Precision digital instrument for accurate grounding resistance measurement.

  • • 2/3/4-Wire Method
  • • Auto Frequency Selection
  • • Anti-Interference Design
  • • Backlit LCD Display
Wireless Phase Detector

Wireless High Voltage Phase Detector

Remote phase verification for high-voltage systems with wireless transmission.

  • • 10kV ~ 500kV Range
  • • Wireless Synchronization
  • • Audible & Visual Alarm
  • • Non-Contact Detection
Multifunction Insulation Tester

Multifunction High Voltage Insulation Tester

All-in-one solution for insulation resistance, polarization index, and dielectric discharge testing.

  • • 250V ~ 5kV Test Voltage
  • • PI, DAR, DD Calculations
  • • USB & Bluetooth Export
  • • Automatic Discharge

Why Choose ETCR?

Safety First Design

All ETCR instruments comply with IEC 61010 safety standards, ensuring operator protection during high-voltage and high-current measurements.

Advanced Technology

Incorporating digital signal processing, wireless communication, and smart algorithms for accurate and reliable results in noisy environments.

Durability & Reliability

Rugged construction, IP-rated enclosures, and long battery life ensure performance in harsh field conditions.

1000+
Units Sold Annually
50+
Global Distributors
15+
Years in Market
98%
Customer Satisfaction

Frequently Asked Questions

What is the difference between clamp-type and digital earth resistance testers?

Clamp-type testers measure grounding resistance without disconnecting the system using a current clamp, ideal for live systems. Digital testers use the 3-pole or 4-pole method with auxiliary electrodes for higher accuracy but require system disconnection.

Can ETCR insulation testers perform polarization index (PI) tests?

Yes, many ETCR high-voltage insulation resistance testers include automatic PI, DAR (Dielectric Absorption Ratio), and DD (Dielectric Discharge) calculation functions for comprehensive insulation assessment.

Do ETCR clamp meters support data logging?

Yes, advanced models like the EM6530 and EM6670D support internal data logging with options to export via USB or Bluetooth to PC or mobile devices.

Are ETCR instruments safety certified?

All ETCR electrical testers are designed and manufactured in compliance with IEC 61010 safety standards for electrical measurement equipment, ensuring CAT III/CAT IV ratings where applicable.

Get in Touch

For product inquiries, technical support, or distributor information, please visit the official ETCR Instruments website.

Visit Official Website

Notice for Buyers: If you are a buyer, the above information is generated by AI collection and does not constitute any advice. If necessary, please visit the corresponding official website.

For Domain Owners: If you are the domain owner and do not want to be included by fobcompany.info, please contact [email protected] via your corporate email to cancel. We will cancel your inclusion within 3 business days.

如果您是域名所有者 不想被fobcompany.info收录 请用企业邮箱联系[email protected] 取消收录 我们将在3个工作日取消您的收录

Service Request: If you are other domain and want to be included, please contact [email protected]

如果您是其他域名合作 也请联系[email protected]